Above Ground Swimming Pool Wiring Diagram
Convenience receptacle outlet shall separate from the pool pump receptacle wiring.
Above ground swimming pool wiring diagram. If the pool is an above ground and is considered storable then the following codes apply. Can be existing and or wired with any approved wiring method see diagram 2 2a b. No further than 20 feet from the outside of the pool wall. All electrical equipment used with storable pools are required to be gfci protected.
Wire the twist lock receptacle. All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection. Minimum 8 awg copper wire ground ring must be installed around the pool 4 to 6 below grade 18 to 24 from the pool and connect to the pump motor heater and the pool water bonding. If a pump motor receptacle is located between.
680 26 b 4 point bonding is not required to the vertical uprights of pools with vinyl liners as it is considered a nonconductive material. Plug in the pool pump and cover it with a weatherproof cover. Electrical wiring requirements for swimming pools permanently installed swimming pools are those that are constructed in the ground or partially in the ground and all others capable of holding water with a depth greater than 42 inches 1067 mm 1 pool pump receptacle outlet and wiring method a. Convenience receptacle outlet must be gfci ground fault protected.
For round pools take the diameter of your pool and add two feet then multiply by 3 14 finally add 25 feet to that.