Carrier 3 Phase Wiring Diagram
Disconnect blue wire from relay 2 terminal 2 and connect to ls1.
Carrier 3 phase wiring diagram. Make sure that the voltage you will be supplying to your motor matches the specifications on the faceplate. Disconnect blue wire from limit switch 3 ls3 cut strip and connect to field wire l3. Disconnect yellow wire from ls1 and connect to ls3. In the united states for low voltage motors below 600v you can expect either 230v or 460v.
Totaline p251 0091 programmable 3 phase voltage monitor the p251 0091 was specifically designed to protect motors and other 3 phase loads from premature failure and damage due to common voltage faults such as voltage unbalance over under voltage phase loss reversal incorrect sequencing and rapid short cycling. Smaller dimension and larger stuffing capacity. 3 6 universal outdoor unit design. Carrier air conditioner wiring diagram to 3 phase jpg in wiring a newbie s overview of circuit diagrams an initial consider a circuit representation might be complicated however if you could read a train map you could review schematics.
Yel lo lo 5. 1 38tra018 048 208 230v 1 phase 60 hertz a96166 320918 401 rev. Figure 5 2 schematic diagram three phase stand by units figure 5 2. 38tra 018 060 60 hertz wiring diagrams fig.
3 7 optional air outlet grille. Simply select the product type the model number and the literature you want and we ll get it to you at the click of a button. On a 3 phase compressor you will see the terminals listed as t1 t2 and t3. Page 43 based on drawing 62 60856 revision e modified for service manual figure 5 2.
A three phase motor must be wired based on the diagram on the faceplate. D notes service valve gauge port may not be equipped with schrader valve valve core. Schematic diagram road only page 2 of 2 62 10630. Well known stable and quiet running fan motor.
That being said there is a wide range of different motors and what you have on hand can be completely different. For 3 phase wiring denotes wire to be moved for 3 phase conversion. Wire type plastic type plastic type. If the 3 phase compressor is a scroll compressor be careful recording which wire is attached to which.
Schematic diagram three phase stand by units page 1 of 2 62 10630. Plastic type and wire type. Call us at 800 743 6009 for replacement parts. If the product information you seek is not listed contact your local carrier expert for assistance to satisfy your information and or system needs.
Dashed wire indicates wiring after conversion. This is different from a single phase compressor which will have 3 terminals listed as s r and c start run and common. See the picture for reference. 3 3 low operation sound level.