Distribution Transformer Connection Diagram
Courtesy midamerican energy co figure 15 4 three phase pad mounted transformer installed in shopping center.
Distribution transformer connection diagram. Conversely the y connection is used for stepping up to a high voltage as in generation station transformer. The 240 v is obtained by making connections between the two ungrounded hot conductors and the 120 v is obtained by making connections between either of the two hot ungrounded conductors and the neutral grounded conductor. Note the fused cutout and lighting arrestor combination external to the transformer. None x4x1 h4 h3 h2 h1 x2x3 primary.
All the diagrams are for additive polarity for three phase transformers. C57 12 70 terminal markings and connections for distribution and power transformers ansi c57 105 guide to three phase transformer connections distribution transformer manual by general electric rus by alexander publications and transformer connections by general electric. 240 x 480 secondary. Distribution transformers 15 3 figure 15 3 two view construction standard detail of a conventional transformer to be installed on the distribution system.
240 x 480 secondary. The dashed lines indicate the transformer outlines. It must be an effective connection and all grounding paths must be connected to it. A transformer can not act as a phase changing device and change single phase into three phase or three phase into single phase.
Figure 2 delta delta transformer connections click to expand diagram the connection diagram on the left shows how a delta delta connection can be made either with three single phase transformers or with one three phase transformer. This separately derived system transformer has a compliant system bonding jumper. To make the transformer connections compatible with three phase supplies we need to connect them together in a particular way to form a three phase transformer configuration. Delta wye three phase transformer connection.
However the required grounding electrode conductor is absent. The grounding electrode makes the earth connection for the transformer secondary circuit. V l is the line to line voltage and v p is the phase to neutral voltage. 120 x 240 secondary.
Generalgeneral electrical connection diagramsacme transformer wiring diagrams primary. Figure 1 is a schematic diagram of a distribution transformer for 120 240 v single phase service. Product literature and application advice were provided by abb. None x4 x1 h4 h3 h2 h1 x2 x3 connect connect primary primary inter secondary volts lines to connect lines to.