How To Wire A Smoke Detector Wiring Diagram
Proper alarm location and placement see alarm placement guidelines connect the alarm to 120v wiring.
How to wire a smoke detector wiring diagram. Locate the junction box and turn off power. The black wire on the detector is also connected to the black wire on the service panel. All mains powered alarms and accessories need a mains supply that is taken from a permanent live feed for example a lighting circuit. 12 3 nmb and ground wire.
The extra run of 4 conductor wire gives us a return path to the panel. Join the black circuit wire s to the black wire lead on the smoke detector. Connect the white circuit wire s with the white wire lead on the smoke detector. For details on how to do this see connecting 4 wire smoke detectors.
Basic electricians pouch of hand tools non metal step ladder and a voltage tester. If you are using a metal box also attach a bare copper or green insulated pigtail wire to the box. To begin turn off power at the junction box and connect the alarm to the building s electrical wiring. In order to connect more smoke detectors for multi level homes or building use three wire cables.
A standard wiring junction box to a 4 inch 10 cm size on either the ceiling or wall. To install the smoke detectors connect a two wire cable from the service panel to the first smoke detector. Understandably the main difference between a wired smoke detector and a battery powered smoke detector is that a wired detector connects directly to wires in your walls. This allows you to locate the end of line resistor and power supervision relay at the alarm panel.
Connect all bare copper ground wires together. The main supply is 120v ac in us and 230v ac in eu. The white wire on the detector is connected to the white wire on the service panel box. Wiring diagrams are included in the instructions supplied with all alarms but here are a few basics.
A smoke or heat detector can be installed to the existing or new home wiring. In our basic wiring diagram a single or multiple heat and smoke detectors are installed in the home by connecting the live line or hot neutral ground and an interconnected wire to the alarm. For 4 wire smoke detector wiring running an extra 4 conductor wire gives the same effect. Wiring smoke detectors electrical project skill level.
Truly we have been realized that how to wire smoke detectors in series diagram is being just about the most popular topic at this time. The connections are to be secured using multipurpose wiring tools.