Mag Ic Flow Meter Wiring Diagram
As illustrated in figures 2 3 and 2 4 avoid downward flows.
Mag ic flow meter wiring diagram. See video instructions here. Upward flow keeps the cross sectional area full regardless of flow rate. I o wiring and specifications 3 6 i o wiring and specifications in the previous section on sourcing and sinking concepts we explained that dc i o circuits sometimes will only allow current to flow one way. Electrical connections b loosen the safety valve c and slide the pump off the brackets d.
Minuto 07 disassembly 7 9. Reference manual 00809 0100 4444 rev ag october 2018 rosemount 8732em transmitter with hart protocol reference manual. The flow meter consists of metal and plastic parts all of which must be in compliance with local rules and. 4 20 internal and external wiring guides for 4 20 as well as 1 5 vdc across a 250 ohm resistor the 0 5 vdc hookup and the pulse counter connections.
Copper wire wafer type sensors common ground plant bonding 2 grounding 4mm 10 awg 2 copper wire common ground plant bonding 2 flow supplied bonding cable grounding ring upstream flange preferably common ground plant bonding 4mm 10 awg copper wire 2 1 full bore sensors caution. The mag meter isolating liner is not intended to be used as gasket material. Flow meter lift the fl ow meter out of the casing assembly and remove the electrical and water circuit connections. This is also true for many of the field devices which have solid state transistor interfaces.
Meter wiring diagrams for low voltage meter stations for in whangarei and kaipara. For applications that require high working pressures or substances that may be hazardous to the. Install the meter with enough room for future access for maintenance purposes. Two page wiring diagram below download here.
Orientation of the electrode plane is unimportant in vertical installations. Vertical installation allows upward process fluid flow and is generally preferred. 6 7 exercise extreme care when withdrawing the electrode from its seat so that little or no tension is exerted on the connecting electrode wire. With the wiring diagram.
The meter must be returned to the factory for electrode replacement. 8 1 2 system diagram 27 8 1 3 mechanical installation 27 8 2 installation 28. These diagrams give the details of the circuitry behind the connections you need to use the mass flow meter. Do not rely on the flange bolts or studs for.
In other words field. When installing the gaskets make sure they are properly centered to avoid flow restriction or turbulence. Pump unhook the pump disconnect the water circuit connections a and from the supports.